PMS Exterior intumescent coating for structural steel
An exterior intumescent steel-protection system for industrial, marine and humid environments, designed together with a compatible primer and sealing topcoat.
Material & applications
Product designation
GT-WRP-Fp2.5-Chnitherm PMS · Exterior intumescent fire-protection coating for steel
Exterior intumescent steel system
PMS protects steelwork in industrial, marine and humid environments with a compatible primer and sealing topcoat. Applications include energy facilities, waterside buildings, aquariums, pools and humid indoor steelwork. Specify member section, film thickness, cellulosic fire requirements and environmental exposure together.
Waterside building applications
Technical data
Technical data & storage
| Property | Requirement / data |
|---|---|
| Mixed density | Approx. 1.23 g/cm³ |
| Mixed weight solids | Approx. 70±2% |
| VOC | 330 g/L; EN ISO11890-1 |
| Flash point | 26°C |
| Theoretical consumption | 500 μm dry / 750–800 μm wet film: 1000 g/m² (0.78 L/m²) |
| Thickness & usage | Dry/wet ratio depends on application; use mass and volume figures in their respective conditions |
| Packaging | 25 kg |
| Base colour | White |
| Finish colour | PMS/TC: RAL; TC726: RAL or NCS subject to the selected finish |
| Storage conditions | Dry, ventilated indoor storage at 5–30°C; never below 5°C; above 25°C reduces shelf life |
| Shelf life | 12 months in sealed original containers under normal conditions |
Application & system
Surface and coating system
Use qualified contractors and trained applicators. Blast-clean steel to ISO Sa2.5 or power-tool prepare to at least ISO St2. Check existing primer thickness and compatibility; repair corrosion and mechanical damage. Apply compatible primer, PMS and Chnitherm PMS/TC sealing finish. Confirm TC726 separately when specifying that finish.
Application and equipment
Brush, roller or airless application is possible. Complex members may need additional passes to reach the required dry-film thickness. First wet coat over primer: 400 μm; subsequent wet coats may exceed 500 μm, subject to sag control. Airless pump ratio ≥45:1, solvent-resistant hose ≥3/8 inch, nozzle 0.46–0.66 mm / 0.019–0.027 inch. Cleaning agent: Chnitherm thinner100; thinning is normally unnecessary.
Substrate & application requirements
| Property | Requirement / data |
|---|---|
| Personnel | Qualified contractor and professionally trained applicators |
| Blast cleaning | ISO Sa2.5 |
| Power-tool preparation | At least ISO St2 |
| Previous coating | Dry and free from contamination |
| Relative humidity | Maximum 85%; prevent condensation; temperature at least 3°C above dew point |
| Surface review | Measure old primer thickness, test compatibility and repair mechanical/corrosion damage |
| Recoat | Completely dry; minimum 16 h, also observe the temperature-specific table |
| Thinning & cleaning | Normally no thinning; clean with Chnitherm thinner100 |
| Brush/roller | Additional coats may be required for complex surfaces and specified dry-film thickness |
| Airless equipment | Pump ratio ≥45:1; remove screens and filters |
| Material hose | ≥3/8 inch, solvent-resistant |
| Nozzle | 0.46–0.66 mm / 0.019–0.027 inch |
| Passes | Multiple passes; first wet coat over primer 400 μm; later wet coats may exceed 500 μm |
| Exterior work | Avoid rain during application/drying; brief light rain only after full drying; seal promptly for exterior use and reinforce marine protection |
Drying & curing
Temperature-dependent intervals
Allow complete drying before recoating. A general minimum of 16 hours does not override the temperature-specific recommendations: at 15°C the recommended recoat interval is 48 hours. Surface dry, through dry and recoat time are separate criteria.
Drying and recoat by temperature
| Temperature | Surface dry | Through dry | Recommended recoat |
|---|---|---|---|
| +15°C | 24 h | 72 h | 48 h |
| +25°C | 12 h | 24 h | 24 h |
| +40°C | 8 h | 24 h | 24 h |
Conditions & precautions
Exterior conditions and safety
Protect from rain during application and drying. An unsealed, fully dry layer tolerates only brief light rain; complete the finish promptly for exterior use and specify additional protection for marine exposure. RH ≤85%; surface ≥3°C above dew point. Confirm the applicable upper substrate-temperature limit. VOC is 330 g/L and flash point 26°C. Follow the current SDS for ventilation, ignition control, transport and disposal.
Documents & specification support
Specify for your project.
Share the application, substrate, area and performance requirements to discuss a coordinated system.