HCF Non-intumescent protection for structural steel
A spray-applied passive protection material based on cement, vermiculite and mineral components, for interior and exterior steel columns, beams and frames.
Material & applications
Product designation
GT-WSF-Fp3.00-Chnitherm HCF · Exterior non-intumescent fire-protection coating for steel
Mineral passive fire protection
HCF combines high-performance cement, vermiculite and mineral components in a spray-applied protective layer for steel columns, beams and frames. Applications include interior and exterior high-rise, industrial, marine, petrochemical, tunnel, metro and underground steelwork. Specify member geometry, thickness and fire exposure together.
Material and finish
The mineral system does not require added emulsion adhesive and contains no reinforcing fibres. Spray application can be followed by surface levelling. Mesh, passes and subsequent decoration depend on the member, substrate and design thickness.
Technical data
Technical performance
| Property | Criteria | Performance |
|---|---|---|
| Condition after mixing | Thick fluid without lumps | Meets requirement |
| Surface drying | ≤24 h | 5 h |
| Initial drying crack resistance | Generally no cracks; 1–3 cracks if present, width ≤1 mm | No cracks |
| Bond strength | ≥0.05 MPa (≥1044 psf) | 0.31 MPa (6474.5 psf) |
| Compressive strength | ≥0.5 MPa (≥10443 psf) | 2.12 MPa (44277 psf) |
| Dry density | ≤650 kg/m³ | 500 kg/m³ |
| Thermal conductivity | ≤0.116 W/(m·K) | ≤0.078 W/(m·K) |
| Water resistance | ≥24 h | 24 h |
| pH | ≥7 | Approx. 12 |
Application & system
Recommended steel system
Prepare the steel, then apply Primer AK2 zinc-phosphate primer, Primer EP61 epoxy intermediate and HCF. Verify adhesion, compatibility and drying; repair corrosion and mechanical damage.
Mixing and spraying
Add water before powder and mix mechanically at low speed until uniform. Use within 4 hours while maintaining agitation. Confirm the water quantity for the application specification. Use a screw, squeeze or mortar pump with compressed air and a mortar spray head, plus pressure-resistant, abrasion-resistant steel-reinforced hose.
Application & packaging
| Property | Requirement / data |
|---|---|
| Surface | Prepare steel for corrosion protection; clean, dry and free from debris; check primer compatibility |
| Mixing | Water first, then powder; low-speed mechanical mixing; use within 4 h with continuous agitation |
| Equipment | Screw, squeeze or mortar pump; compressed air and mortar spray head |
| Hose | Pressure-resistant, abrasion-resistant, steel-reinforced |
| Pump flow | 7–35 L/min |
| Auxiliary air | 0.3–0.4 MPa; 0.4 m³/min |
| Drying | Surface 5 h; through dry 7 days |
| Recoat | Minimum 16 h; check surface condition after extended intervals |
| Weather | 5–40°C; avoid wind and rain; protect during drying |
| Packaging & colour | 25 kg net; grey-white |
Drying & curing
Drying and recoat
Surface dry approximately 5 hours; through dry approximately 7 days. Minimum recoat interval 16 hours. Check actual material condition before further application; surface drying alone does not establish internal drying.
Conditions & precautions
Weather and technical specification
Apply at 5–40°C and avoid high winds and rain. Protect during drying. Evaluate the specified system against the applicable GB14907, EN1363-1 / ISO834, BS476-21, ASTM E119 / UL263 or DIN4102 conditions. Hydrocarbon and tunnel fire exposures require separate assessment; standards are not universal system certifications.
Documents & specification support
Specify for your project.
Share the application, substrate, area and performance requirements to discuss a coordinated system.