PMR Waterborne intumescent coating for timber
A waterborne intumescent coating for specified timber doors, cabinetry and furniture systems. Heat triggers a porous insulating char layer; a compatible topcoat protects the finish.
Material & applications
Product designation
SMT-S/PMR · Intumescent decorative fire-protection coating for timber
Waterborne protection for timber
PMR is an intumescent coating for timber doors, cabinetry and furniture. Heat produces a porous insulating char layer. The formulation contains no APEO or halogens. Performance depends on timber, application rate, thickness and the protective finish. BS476-7 and EN13501-1 C-s2,d0 evaluations must be matched to their tested substrates and conditions; a surface coating does not establish the rating of a complete door.
Intumescence under heat
Porous insulating structure
Coating test scene
Charred specimen
Technical data
Technical data, packaging & storage
| Property | Data | Conditions |
|---|---|---|
| Density | 1.2 g/cm³ | |
| Weight solids | 64±2% | ISO3233-1998 |
| VOC | Approx. 15 g/L | EN ISO11890-1 |
| Shelf life | 12 months, sealed in cool, dry conditions | |
| Theoretical consumption | Approx. 500 g/m² | 300 μm dry film; application and conditions affect usage |
| Curing | Approx. 24 h per coat | 20°C, 65% RH; cold, humidity and thickness extend curing |
| Storage | 5–30°C; sealed, frost-free | 12 months |
| Packaging | 6, 10 or 25 kg pails | |
| Colour | White | Compatible finish selected separately |
Application & system
Preparation and application
Timber moisture must be no more than 15%. Remove dust, grease, adhesive, moisture and incompatible old coatings. Stir thoroughly. Apply by brush, roller or spray; airless nozzle 0.013–0.015 inch, air-spray nozzle no larger than 2 mm. Define consumption and dry-film thickness for the required system.
Protective finish
Allow PMR to dry completely before topcoating. Use a compatible finish against moisture and environmental exposure. For unavoidable outdoor work, avoid rain and apply CHNITHERM TOP726 after drying. Limited rain resistance is not a substitute for a long-term waterproofing design.
Timber-door applications
Drying & curing
Drying and curing
Each coat cures in approximately 24 hours at 20°C and 65% RH. The matrix is in hours and distinguishes wet-film thickness, humidity, temperature and air movement. Low temperature, high humidity and thicker films extend drying.
Drying-time matrix
| RH | Wet film | 10°C still | 10°C airflow | 20°C still | 20°C airflow | 30°C still | 30°C airflow |
|---|---|---|---|---|---|---|---|
| 30% | 0.3 mm | 6 | 2.5 | 4 | 2 | 4 | 1.5 |
| 30% | 0.6 mm | 8 | 3.5 | 6 | 3 | 5 | 2.5 |
| 30% | 1.2 mm | 12 | 4.5 | 8 | 4 | 6 | 3 |
| 50% | 0.3 mm | 10 | 3 | 6 | 3 | 5 | 1.5 |
| 50% | 0.6 mm | 12 | 4 | 8 | 4 | 6 | 3 |
| 50% | 1.2 mm | 18 | 6 | 12 | 5 | 10 | 3.5 |
| 70% | 0.3 mm | 12 | 6 | 10 | 5 | 8 | 3 |
| 70% | 0.6 mm | 18 | 9 | 12 | 7 | 10 | 6 |
| 70% | 1.2 mm | 24 | 12 | 18 | 9 | 12 | 7 |
Conditions & precautions
Conditions and storage
Coating, substrate and ambient temperature must be at least 10°C; RH no more than 80%, with temperature at least 3°C above dew point. Protect the full system from rain until completely dry. PMR is water-sensitive, especially to running water. Store sealed at 5–30°C, protected from frost and sunlight. Do not discharge into water, drains or soil; follow the applicable SDS.
Documents & specification support
Specify for your project.
Share the application, substrate, area and performance requirements to discuss a coordinated system.